for administration: Remove the shield assembly from the supplied B-D ® 10 mL syringe with TwinPak™ Dual Cannula Device (see Figure 1 ) and aseptically withdraw 10 mL of Sterile Water for Injection, USP, from the supplied diluent vial using the red hub cannula syringe filling device. Only use the supplied Sterile Water
Injection, USP for reconstitution. Note
for Injection, USP for reconstitution. Note: Do not discard the shield assembly. Aseptically reconstitute the vial with 10 mL Sterile Water for Injection, USP by directing the stream into the lyophilized powder to obtain a final concentration of 5 mg/mL. Slight foaming upon reconstitution is not unusual; any large bubbles will dissipate if the product is allowed to stand undisturbed for several minutes. Gently swirl until contents are completely dissolved. DO NOT SHAKE. The reconstituted preparation results in a colorless to pale yellow transparent solution. Determine the appropriate dose of TNKase [see] and withdraw this volume (in milliliters) from the reconstituted vial with the syringe. Discard any unused solution.